skip to Main Content
1-760.444.5995 Ex. 1 sales@raveon.com

BASE STATION WILL NOT RECEIVE

Solution #1. Verify that the modem is on the correct RF channel. If it is, the Status LED should blink green every time another modem tries to transmit to it. If the Status LED does not blink when it should…

Read More

NO TRANSMISSIONS OF SERIAL DATA

For the RV-M7 to transmit data, the internal GPS must be receiving a signal. From power-up to reception is about 30 seconds. When the RV-M7 is not locked on to a GPS signal, its power and status LED alternately blink…

Read More

Receive light blinks, but no data is received

Solution #1. Verify Input/Output Configuration. The RV-M7 GX has numerous I/O options. RS232 is standard, but RS485 or RS422 may be configured also. Use the ATIO command to view how the I/O is configured. ATIO 0 is the default (RS232…

Read More

Cannot enter Command Mode

This may be normal. TDMA radios must wait their turn to transmit, and only send data in their proper TDMA time slot. The delay will be the value programmed into the TDMATIME paramter of the radio. Solution #1. Verify the…

Read More
Back To Top